Ballast Power
Lamp Select Switch
The Tegra 4Bank requires 100-240VAC 50/60 Hertz on an earth grounded circuit.
The electronic Ballast operates at a high frequency of 40kHz. It is lightweight,
flicker-free and dead-quiet.
Warning! To Ensure Proper Operation
ALWAYS TURN OFF THE FIXTURE BEFORE
connecting or disconnecting lamps. After the lamps
are properly installed, the in-line switch can turn on
the ballast.
The Tegra 4Bank Universal has four Lamp
Select Switches. Each switch controls one lamp.
Turning off 2 lamps equals a one f-stop reduction in
light output without color shift.
Cold Temperature Operation
The Tegra 4Bank is designed to operate at temperatures from 14F to 122F
(-10C to +50C). In cold temperatures, the ballast may not strike the lamp(s).
Switch the ballast to OFF. Make sure onboard dimmer is full up and re-strike.
Troubleshooting
If the Ballast does not strike after two or three attempts, turn off the Ballast.
With the power switch in the ON position, the red light should be on. If it is not,
Voltage is not present. Check your power feed.
The onboard dimmer should be full up, turned completely clockwise.
All four lamp switches should be in the ON position. Check lamp contact.
Harness color-codes must match at each end of the lamp. Once everything
has been checked, re-strike.