Ballast power lamp select switch – Kino Flo Tegra 4Bank (TEG-400) User Manual

Page 7

Advertising
background image

7

Ballast Power

Lamp Select Switch

The Tegra 4Bank requires 100-240VAC 50/60 Hertz on an earth grounded circuit.
The electronic Ballast operates at a high frequency of 40kHz. It is lightweight,
flicker-free and dead-quiet.

Warning! To Ensure Proper Operation

ALWAYS TURN OFF THE FIXTURE BEFORE

connecting or disconnecting lamps. After the lamps

are properly installed, the in-line switch can turn on

the ballast.

The Tegra 4Bank Universal has four Lamp

Select Switches. Each switch controls one lamp.

Turning off 2 lamps equals a one f-stop reduction in

light output without color shift.

Cold Temperature Operation

The Tegra 4Bank is designed to operate at temperatures from 14F to 122F

(-10C to +50C). In cold temperatures, the ballast may not strike the lamp(s).

Switch the ballast to OFF. Make sure onboard dimmer is full up and re-strike.

Troubleshooting

If the Ballast does not strike after two or three attempts, turn off the Ballast.

With the power switch in the ON position, the red light should be on. If it is not,

Voltage is not present. Check your power feed.

The onboard dimmer should be full up, turned completely clockwise.

All four lamp switches should be in the ON position. Check lamp contact.

Harness color-codes must match at each end of the lamp. Once everything

has been checked, re-strike.

Advertising