Powers LM495 Series Thermostatic Tempering Valves for Individual Lavatory Installations - Quick-Connect Tailpiece Kit User Manual

Installation instructions, Quick-connect installation

Advertising
background image

1. Close the hot and cold water supply valves.
2. Remove the existing union nuts and tailpieces.
3.

Replace with quick-connect tailpieces and union nuts.

Make sure to include fi lter gaskets.

4. Follow quick-connect installation below:

5. Open cold and hot water supplies.
6. Check all connections for leaks.

Quick-Connect Tempering Valve Tailpiece Kit

For Use with Series LM490, LM490-10, LMC490, LM495

Sizes: 1/2", 3/4", 1" (15, 20, 25mm)

Installation Instructions

IS-P-TPK-TV-QC

USA: Phone: 1.800.669.5430 • Fax 1. 847. 229 . 0526 • www.powerscontrols.com

Canada: Phone: 1.888.208.8927 • Fax 1. 888. 882 .1979 • www.powerscontrols.ca

IS-P-TPK-TV-QC 0744

EDP# 6512304

© 2007 Powers

Warranty: The Seller warrants that the equipment manufactured by it and covered by this
order or contract is free from defects in material and workmanship and, without charge, equip-
ment found to be defective in material or workmanship will be repaired, or at Seller’s option
replaced F.O.B. original point of shipment, if written notice of failure is received by Seller
within one (1) year after date of shipment (unless specifically noted elsewhere), provided said
equipment has been properly installed, operated in accordance with the Seller’s instructions,
and provided such defects are not due to abuse or decomposition by chemical or galvanic
action. THIS EXPRESS WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES,
GUARANTEES, OR REPRESENTATIONS, EXPRESS OF IMPLIED. THERE ARE NO IMPLIED
WARRANTIES OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE.
The
Seller assumes no responsibility for repairs made on the Seller’s equipment unless done by
the Seller’s authorized personnel, or by written authority from the Seller. The Seller makes no
guarantee with respect to material not manufactured by it.

Quick-Connect Installation

1. Mark pipe as shown. This is pipe

insertion depth.

2. Clean pipe end.

3. If using PEX tubing, insert pipe

stiffener (provided) into end of
pipe.

4. Push tubing into tailpiece up to

mark.

5. Insert collet clip.

To Connect

PEX tubing only

Pipe Stiffener

Tail Piece

Mark

Collet clip

1

1

/

2

in. (38.1mm)

1

3

/

4

in. (44.45mm)

1

7

/

8

in. (47.63mm)

1

/

2

in.Pipe (12.7mm)

3

/

4

in.Pipe (19.05mm)

1 in.Pipe (25.4mm)

Quick-Connect Kit

IS-P-TPK-TV-QC.indd 1

1/10/08 4:34:32 PM

Advertising