TROUBLE SHOOTING

WARNING

TURN OFF, UNPLUG HEATER AND LET COOL BEFORE SERVICING.
ONLY A QUALIFIED SERVICE PERSON SHOULD SERVICE AND REPAIR
HEATER.

CAUTION

NEVER USE A WIRE, NEEDLE, OR SIMILAR OBJECT TO CLEAN ODS/
PILOT. THIS CAN DAMAGE ODS/PILOT.

OBSERVED PROBLEM


Igniter button is pressed, no
spark at ODS/Pilot













OBSERVED PROBLEM


Igniter button is pressed
Spark at ODS/Pilot
No Ignition

POSSIBLE CAUSE


1. Igniter electrode positioned

incorrectly.

2. Igniter electrode broken
3. Igniter electrode not

connected to igniter cable

4. Igniter cable pinched or wet


5. Piezo igniter nut is loose



6. Broken igniter cable
7. Bad piezo igniter

POSSIBLE CAUSE


1. Gas supply turned off or

manual shutoff valve is
closed

2. Control knob not in PILOT

position

3. Control knob not pressed in

while in PILOT position

SOLUTION


1. Replace igniter

2. Replace igniter
3. Reconnect igniter cable

4. Free igniter cable if pinched

by any metal or tubing. Keep
igniter cable dry.

5. Tighten nut holding piezo

igniter to heater cabinet. Nut
is located inside heater
cabinet at top.

6. Replace igniter cable
7. Replace piezo igniter

SOLUTION


1. Turn on gas supply or open

manual shutoff valve


2. Turn control knob to PILOT

position

3. Press in control knob while in

PILOT position.