1 v-plug, 4 mounting the actuator, 10 drawings – Richter RSS/F Series Bellows-Sealed Control Valves User Manual

Page 16: 1 legend, V-plug 16, Mounting the actuator, Legend, Series rss/f

Advertising
background image

Series RSS/F

Page 16

9260-060-en

Revision 03

TM 7168

Edition 06/2008

9.3.1 V-plug

In contrast to the normal valve plug, the seat
diameter is smaller than the V-plug diameter.
The V-plug is pushed firmly over the resilient sealing
lip of the valve seat. This seals the plug.

9.4 Mounting the actuator

Assembly of the actuator varied depending on the
make and type.
The operating manuals for actuators, positioners
and other accessories must be observed.

As regards the process valve, special attention is to
be paid to the following:

The stem 800 must under no circumstances by
turned to adapt to the coupling 804. If turned
counterclockwise, it would otherwise turn out of the
metal core of the bellows 206.
The actuator manufacturers prescribe that the
valve is moved into the closed position when the
coupling 804 is mounted. In this closed position
many bellows are pre-tensioned in the valve. They
would possibly open the valve again. Therefore,
the stem 800 is to be kept in the closed position
when the coupling 804 is mounted.

The safety function, i.e. opening or closing
of the valve if the air or power fails, must be
checked.

10 Drawings

10.1 Legend

100 body
106 cover

204 plug
205 seat
206 bellows

206

heavy-duty bellows

includes:

231 support

ring

232 support

disc

302/x

guide ring

402/1

packing ring

404

packing nut

405 thrust

ring

508 travel

stop

510 bracket

516 yoke

522 round

cord

523 stroke

index

550 disc
687

protective bellows

includes:

509/1 groove

nut

937/1 clip

954/1 snap

ring

800 valve

stem

801 guide

(DN 80, 100, 3", 4")

804 coupling
850 actuator
901/1 hex.

screw

(DN 15 to 80, ½" to 3" )

902/1 stud

screw

(DN 100, 4")

917/1

screw-in pipe connector

920/x

hex. nut

936/x

tooth lock washer

938/1

hex. head screw plug

Advertising