8 pressure-temperature-diagram, 2 notes on safety, 1 intended use – Richter KNRP-D/F Series Control Ball Valves User Manual

Page 6: 2 for the customer / operator, Pressure-temperature-diagram, Intended use, For the customer / operator, Series series knr/f, knrp/f, knr-d/f, knrp-d/f

Advertising
background image

Series Series KNR/F, KNRP/F, KNR-D/F, KNRP-D/F

Page 6

9520-053-en

Revision 04

TM 7333

Edition 10/2008

1.8 Pressure-temperature-diagram

When used in the minus temperature range,
the regulations applicable in the country in
question must be observed.


A special core material is used for the v-control
ball/stem unit for operating limits under – 10 °C to
– 60 °C.

2

Notes on safety

This

operating

manual

contains

fundamental

information which is to be observed during installation,
operation and maintenance.
It must therefore be read before installation and
commissioning!

For valves which are used in potentially explosive
areas, see Section 3.
Installation, operation and maintenance are to be
performed by qualified staff.
The area of responsibility, authority and supervision of
the staff must be regulated by the customer.

General hazard symbol!
People may be put at risk.

Safety symbol! The valve and its function may
be put at risk if this safety symbol is not
observed.

It is imperative to observe warnings and signs
attached directly to the valve and they are to be kept
fully legible.
Non-observance of the notes on safety may result
in the loss of any and all claims for damages.
For example, non-observance may involve the
following hazards:

Failure of important functions of the valve/plant.
Risk to people from electric, mechanical and
chemical effects.
Risk to the environment through leaks of hazar-
dous substances.

2.1 Intended use

Ball valves are on/off valves.
Richter ball valves are pressure containing compo-
nents in accordance with the Pressure Equipment
Directive (PED) for the passage and shut-off of fluids.
The valves are suitable for vapours, gases and non-
boiling liquids of group 1 according to the PED and
have a corrosion-resistant plastic lining.
Solids can lead to increased wear, damage to sealing
surfaces or to a reduction in the service life of the
valve.
The operator must carefully examine in the event of
operating data other than those provided whether the
designs of the valve, accessories and materials are
suitable for the new application (consult the
manufacturer).

2.2 For the customer / operator

If a valve is used, the operator must ensure that

actuators which are retrofitted are adapted to suit
the valve
hot or cold valve parts are protected by the
customer against being touched
the valve has been properly installed in the pipe
system
the usual flow rates are not exceeded in continuous
operation.

This is not the manufacturer's responsibility.

Advertising