2 notes on safety, 1 intended use, 2 for the customer / operator – Richter GR/F Series Check Valves User Manual

Page 5: 3 improper operation, 1 intended, 2 for the customer / operator 2.3 improper, Operation, Series gr/f

Advertising
background image

Series GR/F

Page 5

9550-075-en

Revision 01

TM 6897

Edition 10/2007

2

Notes on safety

This operating manual contains fundamental
information which is to be observed during installation,
operation and maintenance. It must therefore be read
before installation and commissioning.
For valves which are used in potentially explosive
areas, see Section 3.
Installation and operation are to be performed by
qualified staff.
The area of responsibility, authority and supervision of
the staff must be regulated by the customer.

General hazard symbol!
People may be put at risk.

Safety symbol! The ball valve and its
function may be put at risk if this safety
symbol is not observed.

It is imperative to observe warnings and signs
attached directly to the ball valve and they are to be
kept fully legible.
Non-observance of the notes on safety may result
in the loss of any and all claims for damages.
For example, non-observance may involve the
following hazards:

Failure of important functions of the valve/plant.
Risk to people from electric, mechanical and
chemical effects.
Risk to the environment through leaks of
hazardous substances.

2.1 Intended

use

Richter check valves of the series GR/F are pressure-
maintaining items of equipment in accordance with the
German Pressure Equipment Directive (DGRL) for the
passage of fluids in the direction of the flow arrow
provided on the body and for blocking the passage in
the opposite direction.
The GR/F is intended for horizontal installation.
The valves are suitable for vapours, gases and fluids
of group 1 in acc. with the Pressure Equipment
Directive.
The operator must carefully check in the event of
operating data other than those provided whether the
designs of the strainer, accessories and materials are
suitable for the new application (consultation with the
manufacturer).

.2

For the customer / operator

When using the valve, it must be ensured that

hot or cold valve parts are protected by the
customer against being touched
the valve has been properly installed in the pipe
system
the usual flow rates are not exceeded in continuous
operation.

This is not the manufacturer's responsibility.
Loads caused by earthquakes were not allowed for in
the design.
Fire protection to DIN EN ISO 10497 is not possible
(plastic lining and plastic components).

2.3 Improper

operation

The operational reliability of the valve supplied is only
guaranteed if it is used properly in accordance with
Section 2.1 of this operating manual.

The operation limits specified on the
identification plate and in the pressure-
temperature diagram must under no

circumstances be exceeded.

Advertising