E-10 Error Codes
Writer: M. Church Project: Compaq Professional Workstation AP200 Reference Guide Comments: 352620-003
File Name: L-APPE.DOC Last Saved On: 12/14/98 2:40 PM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
Power-On Self Test Message
Continued
Message
Beeps*
Probable Cause
Recommended Action
Flashing Caps Lock
1L, 2S
Video controller is not present or
is incorrectly initialized.
1. Clear
CMOS.
2.
If video card has
been added,
remove and reseat.
Flashing Scroll Lock
2L, 1S
System board hardware failure
(prior to video)
Replace the system
board.
* L = Long, S = Short
NOTE: If you have replaced the standard keyboard with a Universal Serial Bus (USB)
keyboard, you will hear the beep sequences for these error codes but will not see the flashing
lights.