Operations – Craftsman 65100 User Manual

Page 16

Advertising
background image

16

OPERATIONS

CAUTION: Make certain shipping blocks have been
removed from between cabinet and blower assembly,
before unit is turned on.

FUNCTION

This Air Cleaner is furnished with two filters: an outer
pre-filter which filters particles that are five microns and
larger, and a secondary disposable three-pocket inner
filter that captures 91% of the dust particles that are
one micron and larger (one micron = one millionth of
a meter). The Air Cleaner will filter the air in a room
measuring 20’ x 20’ x 8’ sixteen times an hour. If
desired, multiple units can be used to filter larger areas.

CONNECTING TOOL
TO POWER SOURCE

A separate electrical circuit should be used for your
tools. This circuit should not be less than #14 A.W.G.
wire and should be protected with a 15-amp time lag
fuse. Have a qualified electrician repair or replace dam-
aged or worn cord immediately. Before connecting the
motor to the power line, make certain the switch is in
the “OFF” position and be sure that the electric current
is of the same characteristics as stamped on the motor
nameplate. All line connections should make good
contact. Running on low voltage will damage the motor.

ON/OFF SWITCH

The Air Cleaner is supplied with an in-line rocker switch
(A) located on the power cord. To START or STOP the
unit, press downward on the rocker switch.

DO NOT operate this unit without the filters in place.

NOTE: The Air Cleaner may produce a slight odor for
the first couple hours of operation due to the protective
coating which is applied to internal components. This
odor will dissipate and should be disregarded.

DO NOT USE THIS UNIT TO FILTER METAL DUST.
Combining wood and metal dust can create an explo-
sion or fire hazard. This Air Cleaner is intended for use
where only dry airborne dust is present. Its use should
be limited to non-explosive, non-metallic atmospheres.

NEVER SECURE MOUNTING HARDWARE TO
DRYWALL, DROP CEILING TILE/FRAME OR NON-
STRUCTURAL MEMBERS.

KEEP A MINIMUM OF SEVEN FEET BETWEEN
BOTTOM OF AIR CLEANER AND THE FLOOR.

WARNING

!

WARNING

!

WARNING

!

WARNING

!

Advertising