A.2.1 Verifying the Outgoing ATM ARP Entry

To verify the outgoing ATM ARP cache entry for the endstation originating
the ping, enter the following command on the host:

atmarp -a

The following is an example of a typical ATM ARP cache display:

Outgoing connections:

fa0: ws2-atm (198.29.21.74): vpi.vci=0.100 aal=5

switch.port=-.-

flags=(PVC) encapsulation=NULL peak rate=(unlimited)

fa0: ws3-atm (198.29.21.94): vpi.vci=0.200 aal=5

switch.port=-.-

flags=(PVC) encapsulation=NULL peak rate=(unlimited)

Incoming connections:

fa0: switch.port=-.- vpi.vci=0.100 aal=5 flags=(PVC) decapsulation=NULL

fa0: switch.port=-.- vpi.vci=0.200 aal=5 flags=(PVC) decapsulation=NULL

Make sure the ARP cache entry does indeed match the IP address of the
remote endstation and is using the PVC configured on the switch fabric.

If the prompt is returned with no information displayed, this indicates that
the ATM ARP cache is empty.

Use the following two commands to create a PVC on the host:

./atmarp -s <hostname> <device> <vpi> <vci> <aal>

./atmarp -l <device> <vpi> <vci> <aal>

If the ATM ARP cache entry is valid, then perform the instructions in the next
subsection for atmstat.