Installation

3-1

Manual 0-4965

Drag-gun™ lt

SECTION 3:

INSTALLATION

3.01 Site Selection

• Place in a clean and dry area.
• Provide adequate ventilation and fresh air

supply.

• Ideal ambient temperature should not ex-

ceed 40°C / 104°F. Temperatures exceed-

ing that may diminish cutting capacity or

quality.

• The cutting machine must be placed on an

even, firm surface.

3.02 Electrical Input Connections

• Input voltage is 120V ± 10%, 50/60 Hz

single phase.

CAUTION

Check your power source for correct voltage
before plugging in or connecting the unit. The
primary power source, fuse/breaker, and any
extension cords used must conform to local
electrical code and the recommended circuit
protection and wiring requirements as specified
in Section 2.

3.03 Torch

• Make sure that the torch cable and torch

switch terminals are connected to front

panel.

• Make sure the Work Cable is secured prop-

erly to front panel.

• Before activating, turn torch away from

yourself and others.

DANGER

Do not cut in humid or wet surroundings.

• Before you maintain or replace torch parts,

wait for the post flow air cycle to stop, then

turn the machine off and disconnect from

input power.

• Always use original manufacturers parts.

The use of aftermarket parts could result in

lower parts life and in unsatisfactory cut-

ting results. Any warranty claims would be

waived.

• Recycle worn parts according to local re-

quirements.

NOTE

Repairs must be done by skilled and qualified
personnel only.