CUTMASTER 25MM

Manual 0-5080

SERVICE

5-7

Art # A-07989

1

2

3

4

5

6mm

5. Remove the fitting from the filter element as-

sembly by inserting a 6 mm hex wrench into

the internal hex fitting and turning it counter

clock-wise (left). Numbers 4 and 5 in the previous

illustration.

6. Disconnect the input line from the filter element

assembly.

7. Remove the filter element assembly through the

rear opening.

NOTE

If replacing or cleaning just the filter element

refer to the following illustration for disas-

sembly.

Art # A-07990

Filter Element

8. Install the new or cleaned assembly by reversing

these procedures.

9. Turn ON the air supply and check for leaks before

reinstalling the cover.

Optional Single-Stage Filter Element

Replacement

These instructions apply to power supplies where the

optional Single-Stage Filter has been installed.

The Power Supply shuts down automatically when

the Filter Element becomes completely saturated. The

Filter Element can be removed from its housing, dried,

and reused. Allow 24 hours for Element to dry. Refer

to Section 6, Parts List, for replacement filter element

catalog number.

1. Remove power from power supply.

2. Shut OFF air supply and bleed down system

before disassembling Filter to change Filter Ele-

ment.

3. Disconnect gas supply hose.

4. Turn the Filter Housing Cover counter-clockwise

and remove it. The Filter Element is located

inside the Housing.