04 gas connections, Gas connections -2, Cutmaster 35mm, 40mm – Tweco CutMaster 35mm 40mm User Manual

Page 24

Advertising
background image

CUTMASTER 35mm, 40mm

INSTALLATION 3-2 Manual 0-5118

A. Connections to Three Phase Input Power

WARNING

Disconnect input power from the power supply

and input cable before attempting this procedure.

These instructions are for replacing the input

power and or cable for 400 VAC Power Supply

to Three - Phase input power.

1. Remove the Power Supply cover per

instructions found in section 5.

2. Disconnect the original input power cable

from the main input contactor and the

chassis ground connection.

3. Loosen the through - hole protector on

the back panel of the power supply. Pull

the original power cable out of the power

supply.

4. Using a customer supplied four - con-

ductor input power cable for the voltage

desired, strip back the insulation on the

individual wires.

5. Pass the cable being used through the

access opening in the back panel of the

power supply. Refer to Section 2 for

power cable specifications.

CAUTION

The primary power source and power cable

must conform to local electrical code and the

recommended circuit protection and wiring

requirements (refer to table in Section 2).

6. Connect the wires as follows.

• Wires to L1, L2 and L3 input. It does

not matter what order these wires are

attached. See previous illustration and

on label in the power supply.

• Green / Yellow wire to Ground.

7. With a little slack in the wires, tighten

the through - hole protector to secure the

power cable.

8. Reinstall the Power Supply cover per

instructions found in section 5.

9. Connect the opposite end of individual

wires to a customer supplied plug or

main disconnect.

10. Connect the input power cable (or close

the main disconnect switch) to supply

power.

3.04 Gas Connections

Connecting Gas Supply to Unit

The connection is the same for compressed air

or high pressure cylinders. Refer to the follow-

ing two subsections if an optional air line filter

is to be installed.

1. Connect the air line to the inlet port. The

illustration shows typical fittings as an

example.

NOTE

For a secure seal, apply thread sealant to the

fitting threads, according to manufacturer's

instructions. Do not use Teflon tape as a

thread sealer, as small particles of the tape

may break off and block the small air passages

in the torch.

Art # A-07943

Hose Clamp

Regulator/Filter

Assembly

Inlet Port

Gas Supply

Hose

1/4 NPT or ISO-R

to 1/4” (6mm) Fitting

Air Connection to Inlet Port