Appendix 1: sequence of operation (block diagram), Appendix 1: sequence of operation – Tweco 38 CutMaster User Manual

Page 47

Advertising
background image

Manual 0-2964

A-1

APPENDIX

APPENDIX 1: SEQUENCE OF OPERATION

(BLOCK DIAGRAM)

ACTION

ON / OFF switch

to OFF

RESULT

All indicators off.

Power supply fan shuts off.

ACTION

RUN / SET switch

to RUN.

RESULT

Gas flow stops.

ACTION

Torch moved within

transfer distance of workpiece.

RESULT

Main arc transfers.

Pilot arc off.

ACTION

Close external

disconnect switch.

RESULT

Power to system.

ACTION

RUN / SET switch to SET.

RESULT

Gas flows to set pressure.

GAS indicator on when input

pressure is adequate.

ACTION

Torch moved away

from work (while

still activated).

RESULT

Main arc stops.

Pilot arc automatically

restarts.

ACTION

ON / OFF switch

to ON.

RESULT

AC indicator ON.

Fan on.

Power circuit ready.

ACTION

Protect eyes and

activate torch.

RESULT

Gas flows briefly,

then stops.

Gas restarts.

DC indicator on.

Pilot arc established.

A-03299

PILOT ARC

ACTION

Unplug input

power cord or

open external

disconnect.

RESULT

No power to system.

ACTION

Release torch trigger.

RESULT

Main arc stops.

Gas flow stops after post - flow.

ACTION

Connect work cable

to workpiece.

Set output amperage

RESULT

System is ready

for operation.