Tweco 81 CutMaster User Manual

Page 30

Advertising
background image

OPERATION

4-4

Manual 0-2956

G. Set Operating Pressure

1.

Place the Power Supply RUN / Rapid Auto Restart / SET switch to the SET (down) position. Gas will flow.

Art # A-03592

A

20

40

60

1

2

2.

Adjust gas pressure per the gas settings chart.

Leads

Length

SL60

(Hand Torch)

SL100

(Machine Torch)

Up to 25'

(7.6 m)

70 psi

4.8 bar

65 psi

4.5 bar

Over 25'

(7.6 m)

80 psi

5.5 bar

70 psi

4.8 bar

CutMaster 81 Gas Pressure Settings

Art # A-03581

65 - 80 psi /
4.5- 5.5 bar

Pressure Control Knob /
Bouton De Contrôle
de Pression

Advertising