SECTION 2: SPECIFICATIONS

2.01 Scope of Manual

This manual contains descriptions, operating instructions and basic maintenance procedures for the Thermal Dynam-
ics Automated CutMaster 81 Plasma Cutting System. Servicing of this equipment is restricted to properly trained
personnel; unqualified personnel are strictly cautioned against attempting repairs or adjustments not covered in this
manual, at the risk of voiding the Warranty.

Read this manual thoroughly. A complete understanding of the characteristics and capabilities of this equipment will
assure the dependable operation for which it was designed.

2.02 Power Supply Specifications

Input Power Cable
Output Current
Power Supply Gas Filtering Ability

Ambient Temperature

IEC

Rating

TDC

Rating

IEC

Rating

TDC

Rating

IEC

Rating

TDC

Rating

Duty Cycle
Current

60A

60A

60A

60A

45A

45A

DC Voltage

104V

109V

104V

109V

98V

98V

Duty Cycle
Current

60A

60A

60A

60A

45A

45A

DC Voltage

104V

104V

104V

104V

98V

98V

Duty Cycle
Current

60A

60A

60A

60A

43A

43A

DC Voltage

104V

109V

104V

109V

97V

97V

208/230V

and 460V Units

400V & 415 V Units

600V Units

Input Power

40° C (104° F)

20 - 60 Amps, Continuously Adjustable
Particulates to 20 Microns

CutMaster 81 Power Supply Duty Cycle*

50%

460 VAC (414 - 506 VAC), Three Phase, 60 Hz
600 VAC (517 - 632 VAC), Three Phase, 60 hz
Cable for 208/230 VAC unit includes plug.

400 VAC (360 - 440 VAC), Three Phase, 50 Hz, CE

CutMaster 81 Power Supply Specifications

208 / 230 VAC (187 - 253 VAC), Single Phase, 50/60 Hz
400 VAC (360 - 440 VAC), Three Phase, 50/60 Hz

460 VAC (414 - 506 VAC), Single Phase, 60 Hz

415 VAC (370 - 440 VAC), Three Phase, 50 Hz, CE

* NOTE: The duty cycle will be reduced if the primary input power (AC)

is low or the output voltage (DC) is higher than shown in this chart.

50%

60%

100%

50%

60%

100%

60%

100%

NOTE:

IEC Rating is determined as specified by the International Electro-Technical Commission. These specifications
include calculating an output voltage based upon power supply rated current. To facilitate comparison between
power supplies, all manufacturers use this output voltage to determine duty cycle.

TDC Rating is determined using an output voltage representative of actual output voltage during cutting with a
TDC torch. This voltage may be more or less than IEC voltage, depending upon choice of torch, consumables, and
actual cutting operation.