Installation

3-1

Manual 0-4688

SECTION 3.0

INSTALLATION

3.01 Site Selection

• Place in a clean and dry area.

• Provide adequate ventilation and fresh air sup-

ply.

• Ideal ambient temperature should not exceed

40°C / 104°F. Temperatures exceeding that may
diminish cutting capacity or quality.

• The cutting machine must be placed on an even,

flat surface so that it stands firmly.

WARNING

This equipment must be electrically connected
by a qualified electrician.

3.02 Electrical Input Connections

• Input voltage is 230V ± 10%, 50/60 Hz single

phase.

CAUTION

Check your power source for correct voltage be-
fore plugging in or connecting the unit. The
primary power source, fuse, and any extension
cords used must conform to local electrical code
and the recommended circuit protection and wir-
ing requirements as specified in Section 2.

3.03 Torch

• Make sure that the torch cable and torch switch

terminals are connected to front panel.

• Make sure the Work Cable is connected properly

to front panel.

• Before activating, turn torch away from yourself

and others.

DANGER

Do not cut in humid or wet surroundings.

• Before you maintain or replace torch parts, wait

for the post flow air cycle to stop, then turn the
machine off.

• Always use original manufacturers parts. The use

of aftermarket parts could result in lower parts
life and in unsatisfactory cutting results. Any war-
ranty claims would be waived.

• Recycle worn parts according to local require-

ments.

NOTE

Repairs must be done by skilled and qualified
personnel only.

Advertising