Tweco GC-3000 Gas Control User Manual

Page 19

Advertising
background image

Manual 0-2477

15

INSTALLATION PROCEDURES

5. Secure the assembly to the Rear Panel with the two

nuts provided.

C. Wiring Harness Assembly

1. Locate the Wiring Harness Assembly included with

the Gas Control components.

2. Locate the snap in plug in the Output Connector cut-

out on the Power Supply Rear Panel.

Power Supply

Rear Panel

Output Connector

Snap In Plug

A-01161

Figure 3-10 Output Connector Cutout Plug

3. Place the output connector (J63) on the Wiring Har-

ness Assembly into the cutout.

4. Secure the output connector to the Rear Panel with the

two screws and nuts provided.

A-01162

Mounting

Screws

Output

Connector

Mounting

Nuts

Figure 3-11 Output Connector Installation

5. On the existing wire harness in the Power Supply dis-

connect the connector at J51.

6. Connect the three connectors on the Gas Control Wir-

ing Harness Assembly as follows (refer to the follow-
ing figure for details):

• One connector, 12 circuit, to the Plasma Gas Mani-

fold Assembly (J60)

• One connector, 6 circuit, to the Nitrogen/Other Sec-

ondary Gas Assembly (J61)

• One connector, 8 circuit, to the existing wiring har-

ness connector (J51)

J61

J51

J60

A-01164

Old J51

(No Connection)

Existing Wire Harness

Gas Control

Wire Harness

Figure 3-12 Gas Control Wiring Harness Assembly

Installation

7. Connect the green/yellow ground wire to the ground

stud on the Rear Panel with the nut and washer pro-
vided.

Advertising