Section 4: operation, 01 introduction, 02 functional overview – Tweco 1000 Cutting Systems User Manual

Page 25: 03 getting started, Section 4, Operation -1

Advertising
background image

Manual 0-2710

4-1

OPERATION

SECTION 4:

OPERATION

4.01 Introduction

This Section provides a description of the Liquid Cooled
Model Maximizer 300 Torch Assembly followed by oper-
ating procedures.

4.02 Functional Overview

The Liquid Cooled Model Maximizer 300 Torch is de-
signed to operate with the Merlin 1000 Power Supply to
provide a plasma cutting system which can cut most met-
als from gauge thickness up to 1 inch (25.4 mm). With a
quick change of torch parts the torch can be used for
plasma arc gouging.

4.03 Getting Started

This procedure should be followed at the beginning of
each shift:

WARNING

Disconnect primary power at the source before as-
sembling or disassembling stacked modules, indi-
vidual modules, torch parts, or torch and leads as-
semblies.

A. Torch Parts

Check the torch for proper assembly. Install proper
torch parts for the desired application (refer to Sec-
tion 4.04, Torch Parts Selection).

B. Input Power

1. Check the power source for proper input voltage.

2. Make sure that the Power Supply in the system is

set for the proper voltage (refer to appropriate
Power Supply Operating Manual for connections
or adjustments).

3. Close main disconnect switch or plug unit in to

supply primary power to the system.

C. Work Cable

Check for a solid work cable connection to the work-
piece.

D. Gas Supplies

Select desired gas supplies. Make sure gas sources
meet requirements (refer to Section 2.03, Specifica-
tions & Design Features). Check connections and turn
gas supplies on.

E. Purge System

On the Power Supply place the ON/OFF switch to
the ON position. An automatic gas purge (pre-flow)
will remove any condensation that may have accu-
mulated in the torch and leads while the system was
shut down. The torch cannot be activated during the
purge cycle (pre-flow). After the purge is complete,
if the RUN/SET switch is in SET position, gas will
flow. If the switch is the in RUN position there will
be no gas flow.

F. Current Output Level

At the Power Supply set the desired current output
level for the desired operation.

NOTE

DO NOT exceed the amperage rating of the Torch
Parts (consumables).

G. Pressure And Flow Settings

The pressure and flow settings are made at the Gas
Control Panel on the Plasma Power Supply.

NOTES

Refer to appropriate Plasma Power Supply Oper-
ating Manual for instructions on setting gas flows.

Refer to Appendix 2, Cutting Speed Charts, for
recommended gas pressures and flows for the ma-
terial being cut.

H. Ready for Operation

Return the RUN/SET switch to RUN position.

The system is now ready for operation.

NOTE

Refer to Appendix 1 for a detailed block diagram of
the Sequence Of Operation.

Advertising