CUSTOMER/OPERATOR SERVICE

5-2

Manual 0-2570

Troubleshooting Specific Problems

A. Main disconnect fuse blows when primary power

is connected

1. Voltage selection busbars connected incorrectly

a. Check and correct if necessary.

2. One leg of three-phase primary connected to chassis

ground

a. Rewire input cable

3. Faulty power supply

a. Isolate and replace component(s) per Service

Manual.

B. AC Power Indicator on Front Panel not ON; Fan

OFF

1. Customer’s main power disconnect is turned OFF

a. Turn ON main power disconnect

2. Front Panel ON/OFF switch is turned OFF

a. Turn ON front panel power switch

3. No primary power

a. Check for proper three-phase power at input

terminal board

4. Blown fuse (F2)

a. Check and replace fuse if necessary

5. Faulty power supply

a. Isolate and replace component(s) per Service

Manual.

C. AC power indicator ON; Fan OFF

1. Remote Control or TB2 Enable switch not ON

a. Turn ON switch or enable signal at TB2 in Mas-

ter Power Supply

2. Primary power - missing phase

a. Check for proper three-phase power at input

terminal board

3. Blown fuse (F1 or F2)

a. Check and replace fuse if necessary

4. Power Supply Parallel Cable not installed

a. Connect cable between Master and Slave

Power Supplies

5. Faulty Slave Power Supply

a. Isolate and replace component(s) per Service

Manual

6. Faulty Master Power Supply

a. Isolate and replace component(s) per Service

Manual

D. TEMP indicator ON (red).

1. Unit overheated

a. Allow unit to cool. Check for adequate air flow

around unit

2. Faulty power supply

a. Isolate and replace component(s) per Service

Manual

E. DC indicator OFF (after pre-flow); No main

contactor closure

1. RUN/SET/PURGE switch not set to RUN on Master

Power Supply

a. Normal operation, set switch to RUN position

2. Faulty torch switch, remote control, or remote pendant

a. Isolate and replace component(s) per Service

Manual.

3. Parallel Cable not connected

a. Install Parallel Cable between Master and Slave

Power Supplies

4. Faulty power supply

a. Isolate and replace component(s) per Service

Manual.

F. System cuts at one-half expected current

1. Work lead not connected

a. Check work lead connections from Master and

Slave Power Supplies. Both work leads must
be connected.

2. Slave Power Supply not ON

a. Turn ON front panel ON/OFF power switch

3. Parallel Cable not connected

a. Install Parallel Cable between Master and Slave

Power Supplies

4. Faulty Slave Power Supply

a. Isolate and replace component(s) per Service

Manual

5. Faulty Master Power Supply

a. Isolate and replace component(s) per Service

Manual