INSTALLATION PROCEDURES

3-8

Manual 0-2865

metal. Use lock washers to keep the connections tight.
Using electrical joint compound to prevent corrosion
is also recommended.

6. The plasma power supply chassis is connected to the

power distribution system ground as required by elec-
trical codes. If the plasma supply is close to the cut-
ting table (see NOTE) a second ground rod is not usu-
ally needed, in fact it could be detrimental as it can
set up ground loop currents that cause interference.

When the plasma power supply is far away from the
ground rod and interference is experienced, it may
help to install a second earth ground rod next to the
plasma power supply. The plasma power supply
chassis would then be connected to this ground rod.

NOTE

It is recommend that the Plasma Power Supply be
within 20 - 30 ft (6.1 – 9.1 mm) of the cutting
table, if possible.

7. The plasma control cable should be shielded with the

shield connected only at the cutting machine end.
Connecting the shield at both ends will allow ground
loop currents which may cause more interference than
with no shield at all.

C. Creating An Earth Ground

1. To create a solid, low resistance, earth ground, drive a

1/2 in (12 mm) or greater diameter copper clad ground
rod at least 6 - 8 ft (1.8 - 2.4 m) into the earth so that
the rod contacts moist soil over most of its length.
Depending on location, a greater depth may be re-
quired to obtain a low resistance ground (see NOTE).
Ground rods, typically 10 ft (3.0 m) long, may be
welded end to end for greater lengths. Locate the rod
as close as possible to the work table. Install a ground
wire, 1/0 (53.5 mm

2

) or greater, between the ground

rod and the star ground point on the cutting table.

NOTE

Ideally, a properly installed ground rod will have a
resistance of three ohms or less.

To test for a proper earth ground using 115 VAC, re-
fer to the following diagram. Ideally, the reading on
the multimeter should be 3.0 VAC or less.

3.0

VR COM

A

A-02971

+

_

V

~

Meter set to
VAC setting

Machine

Earth Ground

Neutral

Line (Hot)

100W

Light Bulb

115 VAC

WARNING

Use extreme caution. This

test uses live voltage.

Ground Testing

2. Increasing the ground rod length beyond 20 - 30 ft

(6.1 – 9.1 m) does not generally increase the effective-
ness of the ground rod. A larger diameter rod which
has more surface area may help. Sometimes keeping
the soil around the ground rod moist by continuously
running a small amount of water into it will work.
Adding salt to the soil by soaking it in salt water may
also reduce its resistance. When these methods are
used, periodic checking of the ground resistance is re-
quired to make sure the ground is still good.

D. Routing Of Torch Leads

1. To minimize RF interference, position torch leads as

far as possible from any CNC components, drive mo-
tors, control cables, or primary power lines. If cables
have to pass over torch leads, do so at an angle. Do
not run the plasma control or other control cables in
parallel with the torch leads in power tracts.

2. Keep torch leads clean. Dirt and metal particles bleed

off energy, which causes difficult starting and in-
creased chance of RF interference.