05 input wiring specifications, Input wiring specifications -3, Cutmaster 152 – Tweco 152 CutMaster User Manual

Page 17

Advertising
background image

CUTMASTER 152

Manual 0-4987

INTRODUCTION

2-3

2.05 Input Wiring Specifications

CutMaster 152 Power Supply Input Cable Wiring Requirements

Input

voltage

Freq

Power

Input

Suggested Sizes

Volts

Hz

kVA

I max

I eff

Fuse

(amps)

Flexible Cord

(Min. AWG)

1 Phase

208

60

26.2

126

98

150

4 Type W

230

60

27.6

118

95

125

4 Type W

460

60

35

76

68

100

4

3 Phase

208

60

21.6

60

55

60

4

230

60

22.3

56

50

60

4

380

50

23

35

32

40

8

400

50

23.6

34

31

40

8

460

60

29.5

37

33

40

8

600

60

29.0

28

25

30

10

Line Voltages with Suggested Circuit Protection and Wire Sizes

Based on National Electric Code and Canadian Electric Code

NOTE

Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
The suggested sizes are based on flexible power cable with power plug installations. For hard-wired

installations refer to local or national codes.
I1max is taken at TDC rated minimum duty cycle.