Manual No. 0-5133 Ultra-Cut 200

2-2

SPECIFICATIONS

2.06 Specifications & Electrical Requirements

Maximum OCV (U

0

)

380 vdc

Maximum Output Current

200 Amps

Maximum Output Voltage

230 vdc

Duty Cycle Rating

100% @ 200A, 180vdc (32 kW),
@ 104F° (40°C) Ambient Temperature

Operating range

14°F to 122°F (-10°C to + 50°C)

Power Factor

0.70 @ 100 ADC Output

Cooling

Forced Air (Class F)

Ultra-Cut® 200 Power Supply Specifications

Input

Power Input

Current

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps)

Wire (AWG)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

208

50/60

46

130

160

#1

230

50/60

49

125

150

#1

380

50/60

52

81

100

#4

400 (CE)

50/60

52

77

90

#4

460

50/60

59

75

90

#4

600

50/60

52

51

60

#6

* Suggested wire size based on United States NFPA 70 National Electrical Code 2005 edition
published by the National Fire Prevention Association.
Listings are from rable 400.5(B) for flexible cord of certain types rated for 75 deg. C in ambient
temperatures up to 30 deg. C. Using wires of lower temperature rating or different insulation
type may require larger wire size. Derate for higher ambient temperature.
Wire sizes are suggestions only. Always refer to your local and national codes that apply to
your location for correct wire sizes.

Ultra-Cut 200 Power Supply Electrical Inputs

Suggested Sizes (See Note)