Arcmaster, 160 s – Tweco 160 S Arcmaster User Manual

Page 29

Advertising
background image

ARCMASTER

®

160 S

March 31, 2006

6-1

SECTION 6:

SEQUENCE OF OPERATION

NOTE: Scroll Buttons are used to select the parameters to be set. The LED’s show which

function is being adjusted on the weld sequence graph. Refer to Symbols Table located in

the front of the manual for Symbol descriptions.

3

4

5

1

2

Figure 7-1: 160 S Front Panel

1. Scroll Buttons – used to select the parameter to be set.

The LED’s show which function is being adjusted on the

weld sequence graph.

2. Digital LED display – Welding amperage and parameter

values are displayed in this window. Internal warnings

such as over temperature, low or high input voltage

applied are signaled to the operator by a warning sound

and error message on the screen.

3. Control Knob – allows the operator to adjust the output

amperage within the entire range of the power source,

also used to set each parameter value. Pushing the knob

inward displays the actual welding voltage.

4. Process Button - This button selects between STICK or

LIFT TIG mode.

5. 8 pin remote control receptacle for connecting remote

device. A remote control device is required for use during

LIFT TIG operation. See section 4.01, section 2 “

Remote

Control Socket”, for complete details of the remote

device.

6.01 Stick Welding

• Connect work lead to negative terminal
• Connect electrode lead to positive terminal
• Switch machine on
• Connect remote control device if required

Use the Scroll Buttons to move to the parameter to be set.

The LED will show which function is being adjusted on the

weld sequence graph. Use the control knob to adjust each

parameter.

• Set HOT START
• Set WELD current
• Set Arc Control

Commence welding

6.02 DC Lift TIG Welding

• Connect work lead to positive terminal
• Connect TIG torch to negative terminal
• Switch machine on
• Set WELD current.
• Connect remote control device. A remote control device

is required for use during LIFT TIG operation. See

section 4.01, section 2 “Remote Control Socket

”, for

complete details of the remote device.

Use the Scroll Buttons to move to the parameter to be set.

The LED will show which function is being adjusted on the

weld sequence graph. Use the control knob to adjust each

parameter.

• Set WELD time

Commence welding