Feature Description

Save/Load Function

•

A total number of 5 programs can be saved into the
200 ACDC memory.

SAVE

the Current Weld Parameters into Memory

•

Press and HOLD the

SAVE

button. Beep will sound

and Digital Meter display will show a number 1.

•

Select a memory location by rotating the control knob,
1 to 5 is displayed on the meter.

After selecting the desired memory location (i.e. 1 to 5),
press the right scroll button and the machine will give a
beep to confirm the weld parameters are loaded onto the
control panel.

LOAD

(retrieve) a Program to Control Panel

•

Press and HOLD the

LOAD

button. Beep will sound and

Digital Meter display will show a number 1.

•

Select a memory location by rotating the control knob,
1 to 5 is displayed on the meter.

After selecting the desired memory location (i.e. 1 to 5),
press the right scroll button and the machine will give a
beep to confirm the weld parameters are loaded onto the
control panel.