Tweco 200 ACDC Arcmaster(Feb2006) User Manual
Page 32

26
Feature Description
Save/Load Function
•
A total number of 5 programs can be saved into the
200 ACDC memory.
SAVE
the Current Weld Parameters into Memory
•
Press and HOLD the
SAVE
button. Beep will sound
and Digital Meter display will show a number 1.
•
Select a memory location by rotating the control knob,
1 to 5 is displayed on the meter.
After selecting the desired memory location (i.e. 1 to 5),
press the right scroll button and the machine will give a
beep to confirm the weld parameters are loaded onto the
control panel.
LOAD
(retrieve) a Program to Control Panel
•
Press and HOLD the
LOAD
button. Beep will sound and
Digital Meter display will show a number 1.
•
Select a memory location by rotating the control knob,
1 to 5 is displayed on the meter.
After selecting the desired memory location (i.e. 1 to 5),
press the right scroll button and the machine will give a
beep to confirm the weld parameters are loaded onto the
control panel.