Transtig 170ti – Tweco 170Ti Transtig User Manual

Page 29

Advertising
background image

TRANSTIG 170Ti

Manual 0-5279

3-11

INSTALLATION, OPERATION AND SETUP

When the trigger is pressed, the VRD voltage is activated and the user can start welding as normal. For

extra safety, if welding has not commenced within 3 seconds after the trigger is pressed, the Power Source

will turn off the VRD, and the trigger must be released & pressed again to start welding.

If the trigger is released during welding, all welding power is shut off within the time limits of normal VRD

operation.

A special STICK electrode holder is required for use with a Power Source fitted with a Trigger Switch

function. This electrode holder has a trigger switch attached to it, and a control cable that connects to the

remote control socket of the Power Source. The 170Ti plant comes standard with one of these special

electrode holders fitted with an integrated trigger switch.

The Dead Man Switch function is active in both 2T and 4T STICK mode.

Welding with the Dead Man Switch is as follows:

2T MODE

1. Press the trigger on the electrode holder.

2. The Power Source will now output the VRD volts and the VRD ON led will be lit.

3. Touch the Stick Electrode to the work and commence welding as usual.

4. Release the trigger to cease welding.

There will be 0V on the Power Source welding terminals and both VRD lights will be off.

4T MODE

1. Press the trigger on the electrode holder.

2. The Power Source will now output the VRD volts and the VRD ON led will be lit.

3. Touch the Stick Electrode to the work and commence welding as usual.

4. Release the trigger and continue welding.

5. Press and release the trigger to cease welding.

A-11708

There will be 0V on the Power Source welding terminals and both VRD lights will be off.