18 setup for manual arc (mmaw) welding, Transmig 175i – Tweco 175i Transtig User Manual

Page 37

Advertising
background image

TRANSMIG 175i

Manual 0-5143

3-19

INSTALLATION, OPERATION AND SETUP

CAUTION

Remove any packaging material prior to use. Do not block the air vents at the front or rear of the

Welding Power Source.
Loose welding terminal connections can cause overheating and result in the male plug being fused

in the terminal.

A-09588_AD

""

Work lead

MIG Torch
polarity lead
not connected.

Note: This 8 pin
connection plug is for
TIG torch trigger
connection and remote
TIG torch current
control if applicable.

TIG Torch

Connect to shielding gas
regulator/flowmeter

Negative welding
terminal (-).

Positive welding
terminal (+).

Figure 3-17: Setup for TIG Welding

3.18 Setup for Manual Arc (MMAW) Welding

A. Connect the Electrode Holder lead to the positive welding terminal (+). If in doubt, consult the electrode

manufacturer. Welding current flows from the Power Source via heavy duty bayonet type terminals. It

is essential, however, that the male plug is inserted and turned securely to achieve a sound electrical

connection.

B. Connect the work lead to the negative welding terminal (-). If in doubt, consult the electrode manufacturer.

Welding current flows from the power source via heavy duty bayonet type terminals. It is essential, however,

that the male plug is inserted and turned securely to achieve a sound electrical connection.

!

WARNING

VRD is NOT fitted to Transmig 175i (Asia Version) Plant Part No W1005175M.

!

WARNING

Before connecting the work clamp to the work and inserting the electrode in the electrode holder

make sure the mains power supply is switched off.