05 specifications, Specifications -2 – Tweco FP-165 Mini MIG Portable MIG Welder User Manual

Page 17

Advertising
background image

FIREpOwER Fp-125,135,165

INTRODUCTION

Manual 0-5123

2-2

Introduction

2.05 Specifications

Description

FP-125

FP-135

FP-165

Package System Part Number

1444-0324

1444-0326

1444-0328

Power Source Weight

47.4 lb (21.5 kg)

52.9 lb (24.0kg)

58.1 lb (26.4 kg)

Power Source Dimensions HxWxD

12 x 9.75 x 17.5" ( 304.8 x 247.7 x 444.5mm)

Number of Phases

1 Ø

Frequency

60Hz

Flexible Supply Cable Size

7 ft (2.2 m) 14AWG 7 ft (2.2 m) 14AWG 7.5 ft (2.5 m) 14AWG

Supply Lead Plug Type

5-15P

5-15P

6-50P

Nominal Input Voltage

120V AC

120V AC

230V AC

Rated kVA @ 100% Duty Cycle

5kVA

6kVA

7kVA

Rated Input Current

15A (60A@40%)

15A (60A@60%)

22.5A (120A@25%)

Maximum Input Current

38A (110A@10%)

50A (120A@13%)

35A (155A@15%)

Generator Requirements

# 5kVA

# 6kVA

# 7kVA

Supply VA @ max. output

# 4.6kVA

# 5kVA

# 6.8kVA

Open Circuit Voltage Range

16 – 30V

16 – 32V

15 – 30V

Output Current Range

40 – 125A

39 – 135A

36 – 165A

Duty Cycle Period

10 Minutes

Number of Output Voltage Values

4

Minimum Mains Circuit to suit factory fitted

Plug & Lead (Weld Current @ Duty Cycle)

15A (60A@40%)

15A (60A@60%)

22.5A (120A@25%)

Maximum Mains Circuit to suit factory fitted

Plug & Lead (Weld Current @ Duty Cycle)

38A (110A@10%)

50A (120A@13%)

35A (155A@15%)

Wire Size Range

Steel

.023” - .030” - .035"

(0.6 - 0.8 - 0.9mm)

Stainless Steel

.023” - .030” - .035"

(0.6 - 0.8 - 0.9mm)

.023” - .030” - .035"

(0.6 - 0.8 - 0.9mm)

Flux Core

.030” - .035”

(0.8 - 0.9mm)

.030” - .035”

(0.8 - 0.9mm)

.030” - .035”

(0.8 - 0.9mm)

Table 2-1: System Specifications

The recommended time delay fuse or circuit breaker size is 20 amp. An individual branch circuit capable of carrying 30 amperes

and protected by fuses or circuit breaker is recommended for this application. Fuse size is based on not more than 200 percent

of the rated input amperage of the welding power source (Based on Article 630, National Electrical Code)

Thermal Arc continuously strives to produce the best product possible and therefore reserves the right to change, improve or

revise the specifications or design of this or any product without prior notice. Such updates or changes do not entitle the buyer

of equipment previously sold or shipped to the corresponding changes, updates, improvements or replacement of such items.

The values specified in the table above are optimal values, your values may differ. Individual equipment may differ from the above

specifications due to in part, but not exclusively, to any one or more of the following; variations or changes in manufactured

components, installation location and conditions and local power grid supply conditions.