Section 4: operation, 01 front panel controls and indicators, Section 4: operation -1 – Tweco PC-500 User Manual

Page 27: 01 front panel controls and indicators -1

Advertising
background image

Manual 0-4601

4-1

OPERATION

SECTION 4: OPERATION

4.01 Front Panel Controls and Indicators

(

A) Output Current Control

Sets the desired output current. Output settings up
to 40 Amps may be used for drag cutting (with the
torch tip contacting the workpiece) or standoff cut-
ting.

AC Indicator

Steady light indicates power supply is ready for

operation. Blinking light indicates unit is in pro-
tective interlock mode. Shut unit off, shut off or
disconnect input power, correct the fault, and re-
start the unit. Refer to Section 5 for details.

TEMP Indicator

Indicator is normally OFF. Indicator is ON when
internal temperature exceeds normal limits. Shut
unit OFF; let the unit cool before continuing op-
eration.

GAS Indicator

Indicator is ON when minimum input gas pres-
sure for power supply operation is present. Mini-
mum pressure for power supply operation is not
sufficient for torch operation.

DC Indicator

Indicator is ON when DC output circuit is active.

ON / OFF

Switch

Controls input power to the power supply. Up
is ON, down is OFF.

RUN

/ RAPID AUTO RESTART

/

SET

Switch

RUN

(up) position is for general torch operation.

RAPID AUTO RESTART

(middle) position is for an uninterrupted restart,

when cutting expanded metal or in gouging or trimming operations.

SET

(down) position is for setting gas pressure and purging lines.

20

30

40

25

35

A

A-03742

Advertising