OSRAM SYLVANIA ProPoint Outdoor Luminaire Small Cobrahead User Manual

Propoint, Outdoor luminaire small cobrahead

Advertising
background image

ProPoint

TM

Outdoor Luminaire Small Cobrahead

(SC)

Installation Guide


 
 

Risk of fire or electrical shock. Install this 
module only in the luminaires that have the 
construction features and dimensions shown in 
the photographs and/or drawings      
 
Do not make or alter any open holes in an 
enclosure or wiring or electrical components 
during modules installation   
 
To ensure personal safety, proper grounding is 
required     
 
Light engine module installation requires 
knowledge of luminaire electrical systems. If not 
qualified, do not attempt installation. Contact a 
qualified electrician 
 
To prevent wiring damage or abrasion, do not 
expose wiring to edges of sheet metal or other 
sharp objects          
 
 

 

Cobrahead Fixture available in 55, 80,
100 and 120 Watts, mounts easily on a
1 ¼” NPS or 2” NPS arm

www.sylvania.com

Safety Warnings:

Luminaire Installation:

Open the luminaire by pulling the trigger latch toward the nose of the fixture.
Swing the lower housing (door) away from the upper housing. Disconnect
wiring harness plug. When the lower housing is opened to 135 degree, the
lower housing can be removed from its hinges for easier installation of
upper housing.

Determine the size of the mast arm. This luminaire is designed
to optimally accommodate a 1-1/4”-2” mast arm. Tighten
mounting bolts 10-15 ft-lbs

Trigger Latch

SC Upper Housing

PEC Receptacle

Hinge

SC Lower Housing (door)

Lens

 / Reflector 

Mast Arm

Fitter Clamp

Fitter Bolt

Leveling Steps

SC Upper Housing with Lower Removed

Loosen the two fitter bolts in the upper housing. Lift the upper
housing into position in front of the mast arm so that the mast
arm enters opening at the rear of the housing and extends into
the fixture between the fitter clap and the luminaire leveling
steps. Using the cast leveling steps, adjust the luminaire to the
desired mounting angle. Fully tighten fitter clamp bolts (10-15 ft-
lbs).

 

Mast Arm Opening

LED178 