Irving oil – Vermont Casting IRFSDV24 User Manual

Page 11

Advertising
background image

11

Irving Oil

10004000

Horizontal Dimension From The Outside Face Of The

Wall To The Center Of The Fireplace Vent Flange

Vertical Dimension From The Floor Of The Fireplace

To The Center Of The Horizontal Vent Pipe

TO USE THE VENT GRAPH

SIDEWALL VENTING GRAPH

(

Dimensions In Feet)

1. Determine the height of the center of the horizontal

vent pipe exiting through the outer wall. Using this
dimension on the Sidewall Vent Graph below, locate
the point it intersects with the slanted graph line.

2. From the point of this intersection, draw a vertical

line to the bottom of the graph.

3. Select the indicated dimension, and position the

fireplace in accordance with same.

Example A:

If the vertical dimension from the floor of the
fireplace is 11’ (3.4m) the horizontal run to the face
of the outer wall must not exceed 14’ (4.3m).

Example B:

If the vertical dimension from the floor of the unit is
7’ (2.14m), the horizontal run to the face of the

outer wall must not exceed 8-1/2 (215mm).