ClearOne Musica Tools User Manual

Page 20

Advertising
background image

MusicaTools User’s Guide

3-2

PN: 020002

All specifications subject to change without notification. All rights reserved. Copyright © 2006 NetStreams

Main +1 512.977-9393 / fax +1 512.977.9398 / Toll Free Technical Support +1 866-353-3496

3600 W. Parmer Lane, Suite 100; Austin, TX 78727 /

www.netstreams.com.

1

Rooms - information for up to six rooms connected to the ADC you are monitoring

2

toggle switch for settings and status

3

source selection - for selecting sources 1 to 4

4

IR Freq - 38 kHz or 56 kHz

5

keypads

ˆ

press and hold (2nd key) selection

ˆ

ten IR commands and mode selection

6

IR Data - allows you to upload or download the IR commands between PC and
ADC

7

command selection (used as shortcuts to build RS-232 commands):

ˆ

State

ˆ

Chang

ˆ

Nudge

8

sub_command - a list of sub commands for use as programming shortcuts

9

manual entry window - field where RS-232 commands are entered

10

monitor window - displays a history of previously enter RS-232 commands

11

Clear monitor - clears everything in the monitor window

12

Copy - copies selected command and sub command into the manual entry window

13

Firmware Version. Check the ADC firmware version to ensure you have the most
current on your system. Settings is only available when online mode is selected.

14

Global command - applies the commands set up in MusicaTools for the first
programmed keypad to all other keypads.

NOTE:

Global Command works for up to 18 zones.

15

Event subscribe - when checked, any values that change on the ADC are reported
in the monitor window.

16

Settings - opens the Settings window.

17

Offline/Online toggle - connects or disconnects MusicaTools from the attached
system.

Advertising