SECTION 6: Maintenance and Troubleshooting

Preventive Maintenance

WARNING

LMA requires periodic inspection and maintenance to perform optimally and achieve maximum

operation life.

WARNING

The intervals shown are recommended. Maintenance schedules should be more frequent for

higher use areas.

Area

Maintenance

Period

(Month)

1

VESA Adapter
• Check if the adapter plate and the monitor are securely attached. Ensure the four screws on the

mounting plate(s) are fastened to the tightest possible position.

• Visually inspect for any signs of grinding and gapping.

4

2

MRS Rail Mount Adapter
• Ensure the two set screws on the channel are fastened to the tightest possible position.

1

3

Swivel Joint
• Ensure screw on bottom of joint is fastened to the tightest possible position using a #3 Philips head

screwdriver.

• Ensure set screw at back of joint is tightened. Use a 2.5 mm HEX key to tighten as needed.

1

Troubleshooting

Symptom

Possible cause

Solution

Too easy or too difficult to tilt the monitor

up and down

• Excessively loosened or tightened

hardware

• Adjust respective screws to control the

correct movement

Too easy or too difficult to utilize the

portrait/landscape feature

• Weight of the monitor is not compatible

with the arm

• Please contact Amico Accessories Inc.

The entire arm is rocking slightly when in

use

• Damaged hardware

• Please contact Amico Accessories Inc.

Length of the extension arm is at an angle

• Loosened/damaged hardware

• Perform preventive maintenance
• Check all screws are secured
• Please contact Amico Accessories Inc.

Extension arm is not secure or it is rocking

slightly

Arm is too difficult to maneuver with the

monitor

• Damaged extension arm
• Weight of the monitor exceeds the load

rating

• Please contact Amico Accessories Inc.

Arm falls to the lowest position on its own

when monitor is attached

• Counterbalance is not adjusted properly

for devices

• Adjust for the correct counterbalance
• See section 4: adjustment procedure

Excessive gapping or angling at joints of

arm

• Damaged hardware or other physical

damage

• Equipment is too heavy

• Check device mounted for weight

compatibility. If problem persists

contact Amico Accessories Inc.

If the above solutions do not solve your symptoms or you are in need of parts/hardware, please contact Amico