Appendix F

Liquid Manifold with High Pressure Reserve

40 [1016]

Dependent upon type

of Liquid cylinder used.

60

[1524]

40 [1016]

60

[1524]

Minimum tank pressure

must be at least 300 psi

for Liquid Nitrogen and

200 psi for all other gases.

Minimum tank pressure

must be at least 300 psi

for Liquid Nitrogen and

200 psi for all other gases.

H.P. Vent

(1/2" NPT)

Approx.

Approx.

Push

To

Start

OXYGEN

Top View

Set at 1100 psi Decreasing

Set Reg. to 80 - 85 psi

110 psi NFPA Relief Valve

Set at 85psi Decreasing

Piping Not Included

5

4

3

8

7

6

2

1

2

Relief Valve Vent 1/2” (NPT)

Supply Line

Provision for Reserve Manifold

(1) M3A-DS-LL-U-OXY
(2) M2-HBLQ-02U-OXY
(3) M-PRSW-GA-ORES
(4) M-SIMP-U-08-OXY
(5) M-PRSW-RES-OXY
(6) M-X-MAN-72W-125
(7) VV-CHK-(PIPE SIZE)
(8) VV-ISO-G-(PIPE SIZE)