Part 6 - Diagnostic Data

HB-0846-03

6-11

6.4

HALCYON 2000 COMPASS


6.4.1

Shows Heading and CAL Flashing


Symptom:
Display flashes a Heading and CAL

Possible Causes:


(a) The memory in the Halcyon 2000 is empty or has
been corrupted. This may be due to a System Reset
being performed or the first time the compass has been
installed and not yet been calibrated. Perform a
calibration swing to restore normal operation.

(b) After a calibration swing the result is always FAIL.
There is a source of magnetic deviation near to the
Halcyon 2000 compass. Try re-positioning the compass
and perform the calibration.

6.4.2

Heading Shows Err


Possible Causes:


(a) The signal from the fluxgate sensor is too big or too
small. Try re-positioning the compass. If still showing Err
set NAVIGATE

? COMP CAL, CAL VAL 2 (RES CAL) to

1. This will reset the compass (see 4). All previous
calibrations will be lost.

6.4.3

Heading or COMP CAL Shows PHS


Possible Causes:


(a) The compass is in the middle of resetting, the display
should show heading and CAL flashing after 20 seconds.
A calibration swing will be required.