Tank Level Sensing Processor and Sensors

Page 6

6.4 Installation of the Sensor Module

1.

Select a dry location above the tank height and, using the dimensions from the

template below to ensure adequate clearance from other equipment or structures, drill the
mounting holes for the unit. Using the self-tapping screws supplied secure the Sensor
Module.

Note:

The Sensor Module must not be submerged. Install the module with the tubing

and cable entries facing downward to prevent dust and debris from blocking the filter.

2.

Secure the tubing so that no kinks occur and firmly push the free end of the

Swagelock tubing to the quick connect fitting on the sensor module.

3.

The tank sensor module must be mounted within 3m of the tank insert.

127mm

2mm

45mm

WARNING: THIS DIAGRAM IS NOT DRAWN TO SCALE.