T k 4 t x t – B&G H2000 Pilot *DISCONTINUED* User Manual

Page 15

Advertising
background image

Tank Level Sensing Processor and Sensors

Page 11

An example is shown, setting tank 4 input.

S F B A L P C

7 5 .3

4

T K 4 T X T

To avoid confusion, it is not possible to assign the same text to 2 different sensor inputs. If
the text is changed, the sensor input associated with that text will change to display TANK
xx
, until it’s CAL VAL 4 is also changed.

If CAL VAL 4 is set to 0, TANK xx will be displayed.

Using a PC attached to the TLSP, it is possible to assign custom labels up to 8 characters
in length to the tank sensor inputs. When custom text has been assigned to a tank input,
requesting CAL VAL 4 will result in the text CuSt being displayed. The PC will be the only
method of changing the text.

7.1.3 Units

The information from the tank sensor is viewed via the FFD under the menu heading of
TANKS. Although up to 12 tanks can be measured, the actual number of sensors connected
may be selected and the associated text assigned to each.

The information relating to the various tanks may be displayed in the following units:

Percentage

PC

1% increments - (0% to 100%)

Litres

Lt

1L increments - (0L to 999L)

US Gallons

UG

1/2G increments - (0G to999.5G)

Imperial Gallons

IG

1/2G increments - (0G to 999.5G)

Advertising