5.10.2 Linear Function Settings

Altering calibration value 1 (CAL VAL 1) allows the correct input sensor to be
selected. The different inputs available are shown below:

1 or 2

normal linear input 0 to 1000

3

rotating mast correction for apparent wind angle

4

heel angle

5

trim angle

6

barometric pressure

7

rudder angle

8

air temperature


The default factory setting for a linear input is 1 (0-1000 format).

Note
Do not set different linear inputs to the same function (except 1 for normal
linear input) or the calibration value will be ignored. This ensures that no
function uses no more than one analogue input. However, any one of the
Linear 1 to 4 inputs from the main processor may be set to the same
function as any one of the Linear 5 to 16 inputs.
Calibration value 2 (CAL VAL 2) displays MIN VAL with a number that can be
adjusted between -999 and 9999. This is the number to be displayed for a
0V input. The default setting is 000.

Calibration value 3 (CAL VAL 3) displays MAX VAL with a number that can
be adjusted between -999 and 9999. This is the number to be displayed for
6.5V input. The default setting is 1000.

5.10.3 Calibrating a Linear Channel

Adjusting the MIN and MAX values allows the displayed value to be scaled to
the appropriate range for the sensor attached. Taking a load cell for
example, if the zero load output is 0V, MIN VAL=000 and if maximum load is
650 kgF at 6.5V then MAX VAL=650.

Calibration value 4 is only available on Linear 5 and this displays a value
between 05 and 16. This setting determines the number of linear inputs that
are available. For example, changing this value to 10 would display a
maximum of 10 linear inputs. The default value is 05.

Damping is adjustable between 0 and 99 seconds. The default setting is 01.