B&G H2000 Pilot *DISCONTINUED* User Manual
Page 141

HB-0844-04
5-24
Notes
1. When calibration value 1 is changed to select a desired input sensor, the
linear value is no longer updated and a constant value is displayed until the
page key is pressed.
2. Extra functions selected, and then removed, remain in the display menu
but with no data shown until the system is switched off and then back on
again.
3. Linear functions will always be shown if selected by CAL VAL 4 on linear
5. They will show no data if the CAL VAL 1 setting is configured to 1 or 2.
5.9.4
Expansion Processor Wiring
The Expansion Processor is connected to the system Fastnet for power and
data requirements.
TERMINAL
FUNCTION
WIRE COLOUR
1
Meter 5 SIN
Green
2
Meter 5 COS
Blue
3
Meter 6 SIN
Red
4
Meter 6 COS
Violet
5
Meter 7 SIN
Red
6
Meter 7 COS
Violet
7
Meter 8 SIN
Green
8
Meter 8 COS
Blue
9
Meter Lighting
Yellow
10
Meter Common
Orange
11
Meter Ground
Black
12
N/C
13
N/C
14
Network Data -ve
Green
15
Network Data +ve
White
16
Network Screen
Screen
17
Battery Supply
Ground
Black
18
Battery Supply 12V
Red
19
Battery Volts Sense
Link to 18
20
N/C
21
Ground
Blue
22
Sensor Supply
+6.5V
Red