post, and the RED wire to the POSITIVE (+)
post. Replace the wing nuts and tighten.

7. Replace the cover on the battery box.

8. Plug the charger and the blue AC controller

back into the outlet.

9. If any of the alarms are sounding, press the

YELLOW button on the front of the control
panel for one (1) second.

4

Pump

When the water rises in the sump pit and
activates the float switch, the pump will begin
pumping, and the “Pump was activated” light
and alarm will turn on. Try to determine what
caused the system to activate.

• Check the main AC pump for failure. It may

not be working, the float switch may be stuck,
or it may be too small to handle the inflow of
water.

• Make sure the check valve is working

• Make sure the discharge pipe is not clogged or

frozen

• If the power was out, the backup pump was

automatically activated and protected your
basement. You need to push the YELLOW
button on the front of the control panel to
silence the alarm.

REPLACING THE BACKUP PUMP

Before you begin
this process you
will need a new
backup pump. You
may also want to
change the check
valves at this time.
The backup pump
uses a 1-1/4” check
valve, the primary pump uses a 1-1/2” check
valve. (See parts list on page 13.)

Risk of electrical shock or battery explosion,
which can cause serious injury or death.
Wear eye protection. Work in a well-
ventilated area. Do not smoke or allow a

spark or flame in the vicinity of the battery.
Avoid dropping metal tools on the battery.
Review the safety instructions on page 1.

REFER TO THE PHOTOS AT RIGHT

1. Unplug the primary pump from the blue

controller.

2. Remove the charger plug from the back of the

black controller.

3. Unplug the backup pump from the back of the

black controller.

4. Remove the sensor from the battery.

5. Remove the battery wires from the battery

terminals. Be sure they do not touch each
other while one is connected to the battery.

6. Slowly loosen the rubber union on the top of

the combination pump assembly to separate
the pipes. The water trapped in the pipe will
pour out into the sump as the rubber union is
loosened.

7. Separate the pump assembly from the rubber

union and lift it out of the sump by the
handle on the primary pump.

8. Turn the assembly up side down over the

sump pit to allow the remaining water in the
system to drain.

9. Loosen the screws on the no-hub connector

on the elbow of the backup pump.

10. Unscrew the screw on the bottom of the

pump bracket with a Phillips head
screwdriver, and lift the pump off of the
bracket. Then pull the pump down out of
the no-hub connector.

11. Unscrew the check valve on the elbow of the

backup pump. Now reverse the process.

12. Screw the check valve on to the new pump.

(You can use the existing check valve, or
preferably replace it with a new one.)

13. You must drill a 1/8” hole in the elbow of

the new pump to prevent an air lock in the
system. An air lock will prevent the pump
from operating. Drill the hole on a
downward slope below the check valve on
the elbow.

14. Push the pump and check valve back up into

the no-hub connector, and place the pump
on the pump bracket.

15. Screw the pump onto the bracket.

16. Tighten the hose clamp on the no-hub

connector.

17. Lower the pump system back into the sump

pit.

18. Connect the top of the system to the rubber

union and tighten the hose clamp.

19. Connect the battery cables to the battery

terminals, BLACK to the NEGATIVE (-) post,
and RED to the POSITIVE (+) post.

20. Insert the fluid sensor into the top of the

battery.

21. Plug the backup pump into the back of the

black controller.

22. Plug the charger into the back of the black

controller.

23. Plug the primary pump into the blue

controller.

!

DANGER

2,3

1

Remove

4,5

7

6

8

9

10

YOU WILL BE DISCONNECTING ALL THE
WIRES. BE SURE THEY DO NOT FALL INTO THE
SUMP PIT. SEE DIAGRAM ON PAGE 12 FOR
PARTS DESCRIPTION.

FUSE

CHARGER

PUMP

13

11