Service and adjustments – Craftsman 919.167551 User Manual

Page 16

Advertising
background image

16- ENG

5. Unscrew

Check

Valve

Outlet

Tube

Nuts

the

check

valve

(turn

counter-

clock-

wise)

using a

7/8"

open

end

wrench.

6. Using a screwdriver, carefully push

the valve disc up and down.

In closed position

disc is visible.

In open

position

nothing is

visible.

Screwdriver

NOTE: The valve disc should move

freely up and down on a spring which

holds the valve disc in the closed posi-

tion; if not the check valve needs to be

replaced.
7. Install the new check valve (turn

clockwise).

8. Replace the outlet tube and tight-

en nuts.

9. Replace the shroud.

SERVICE AND ADJUSTMENTS

Risk of Unsafe

Operation. Unit

cycles automatically when power

is on. When servicing, you may

be exposed to voltage sources,

compressed air, or moving parts.

Before servicing unit unplug or

disconnect electrical supply to

the air compressor, bleed tank

of pressure, and allow the air

compressor to cool.
ALL MAINTENANCE AND REPAIR

OPERATIONS NOT LISTED MUST

BE PERFORMED BY TRAINED

SERVICE TECHNICIAN.

TO REPLACE CHECk VALVE

1. Release all air pressure from air

tank. See

To Drain Tank in the

Maintenance section.

2. Unplug outfit.
3. Remove the shroud on the outlet

tube side.

NOTE: Remove screw

with T-20 Torx screwdriver and

loosen all the tabs on the shroud

with a flat screwdriver before

removing.

4. Using an adjustable wrench, loos-

en outlet tube nut at air tank and

pump head. Carefully move outlet

tube away from check valve.

Advertising