Storage – Craftsman 919.167551 User Manual

Page 17

Advertising
background image

17 - ENG

TO REPLACE REGULATOR

1. Release all air pressure from air

tank. See

To Drain Tank in the

Maintenance section.

2. Unplug compressor.
3. Remove shrouds.
4. Remove the outlet pressure gauge

and quick connect from the

regulator.

Outlet

Pressure

Gauge

Regulator

Quick

Connect

5. Remove the regulator.
6. Reapply pipe sealant to outlet

pressure gauge and quick

connect.

7. Assemble quick connect to new

regulator and tighten.

Regulator

Arrow

Quick

Connect

Nipple

8. Apply pipe sealant tape to the

nipple.

9. Assemble the regulator.

NOTE:

Arrow indicates flow of air. Make

sure it is pointing in the direction

of air flow.

10. Use the hex on quick connect

to tightening regulator. Orient as

shown.

11. Assemble outlet pressure gauge.

Orient outlet pressure gauge to

read correctly.

12. Replace shrouds.

STORAGE

Before you store the air compressor,

make sure you do the following:
1. Review the Maintenance section

on the preceding pages and per-

form scheduled maintenance as

necessary.

2. Drain water from air tank. See

To

Drain Tank under Maintenance.

Water will

condense in the

air tank. If not drained, water will

corrode and weaken the air tank

causing a risk of air tank rupture.

3. Protect the electrical cord and

air hose from damage (such as

being stepped on or run over).

Wind them loosely around the

compressor handle.

4. Store the air compressor in a

clean and dry location.

Advertising