Figure 7-9 – Cisco 5500 User Manual

Page 12

Advertising
background image

7-12

Cisco MGC Software Release 7 Operations, Maintenance, and Troubleshooting Guide

OL-0542-06

Chapter 7 Maintaining the Cisco Catalyst 5500 Multiswitch Router

Replacing Hardware Components

Step 2

Turn the power switch to the OFF (0) position on the power supply you are removing (see

Figure 7-9

).

Step 3

Remove the two screws securing the terminal block cover and slide the cover straight off the terminal
block (see

Figure 7-9

).

Figure 7-9

DC-Input Power Supply Front Panels

Step 4

Disconnect the DC-input wires from the terminal block. Disconnect the ground wire last.

Step 5

Disconnect the central office (CO) ground from the CO ground connector (

Figure 7-10

).

Figure 7-10 DC-Input Power Supply CO Ground

Step 6

Loosen and remove the captive screws on the power supply (see

Figure 7-9

).

Caution

Use both hands to remove and install power supplies.

Step 7

Grasp the power supply handle with one hand and place your other hand underneath as you slowly pull
the power supply out of the bay (see

Figure 7-11

).

H8767

0

I

OK

OK

FAIL

DC

FAN OUTPUT

Terminal

block

cover

Remove

Captive screw

Remove

Power

switch

28649

o

CO ground

connector

location

o

PS1

PS2

FAN

LINK

SLOT 2

SLOT 1

PCMCIA

EJECT

Enet

RX

TX

RESET

SWITCH/PROCESSOR

Advertising