Canon EOS 40D User Manual

Page 183

Advertising
background image

183

Specifications

AF point selection:

Automatic selection, manual selection

Selected AF point display: Superimposed in viewfinder and indicated on LCD panel
AF-assist beam:

Small series of flashes fired by built-in flash
Effective range: Approx. 4.0 m/13.1 ft. at center, approx.
3.5 m/11.5 ft. at periphery

• Exposure Control

Metering modes:

35-zone TTL full-aperture metering
• Evaluative metering (linkable to any AF point)
• Partial metering (approx. 9% of viewfinder at center)
• Spot metering (approx. 3.8% of viewfinder at center)
• Center-weighted average metering

Metering range:

EV 1 - 20 (at 23°C/73°F with EF50mm f/1.4 USM lens, ISO 100)

Exposure control:

Program AE (Full Auto, Portrait, Landscape, Close-up, Sports,
Night Portrait, Flash Off, Program), shutter-priority AE, aperture-
priority AE, depth-of-field AE, manual exposure, E-TTL II autoflash

ISO speed (Recommended
Exposure Index):

Basic Zone modes:ISO 100 - 800 set automatically
Creative Zone modes: ISO 100 - 1600 (in 1/3-stop increments), Auto,

or ISO speed can be expanded to ISO 3200

Exposure compensation: Manual: ±2 stops in 1/3- or 1/2-stop increments (can be

combined with AEB)
AEB: ±2 stops in 1/3- or 1/2-stop increments

AE lock:

Auto: Applied in One-Shot AF mode with evaluative

metering when focus is achieved

Manual: By AE lock button

• Shutter

Type:

Electronically-controlled, focal-plane shutter

Shutter speeds:

1/8000 to 30 sec. (1/3- and 1/2-stop increments), bulb, X-
sync at 1/250 sec.

Shutter release:

Soft-touch electromagnetic release

Self-timer:

10-sec. or 2-sec. delay

Remote control:

Remote control with N3 type terminal

• Built-in Flash

Type:

Retractable, auto pop-up flash

Flash metering:

E-TTL II autoflash

Guide No.:

13/43 (ISO 100, in meters/feet)

Recycle time:

Approx. 3 sec.

Flash-ready indicator:

Flash-ready icon lights in viewfinder