3. REPLACING THE LASER SIGHT BATTERIES

ATTENTION: THIS LASER TARGET DESIGNATOR IS A POWERFUL DEVICE
THAT REQUIRES SPECIAL ATTENTION FOR ITS USE. READ THE FOLLOWING
INSTRUCTIONS AND SAFETY PRECAUTIONS CAREFULLY BEFORE USE.

CAUTION: USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE
PROCEDURES OTHER THAN THOSE SPECIFIED HEREIN MAY RESULT IN
HAZARDOUS RADIATION EXPOSURE.

LASER LIGHT - AVOID DIRECT EYE EXPOSURE.

KEEP OUT OF REACH OF CHILDREN.

Remove the push button assembly (located in the rear end of the laser) by turning it
counter clockwise. Place the 1 CR123A battery inside, with the positive end facing
out. Replace the push button assembly or the momentary pressure switch securely
by turning it clockwise until tight. The laser is now ready for use.

4. ZEROING THE LASER SIGHT

First align laser with the path of the pellet/ bullet. Follow the steps below.

1) Activate laser by pressing the momentary pressure switch (or push button).

2) From a bench rest position, fire three shots at

the center of the target.

3) Observe where the pellets or bullets strike the

target. Keeping the laser dot pointing at the
center of the target and using the windage and
elevation adjustments screws located in the
laser body move the laser dot to the center of
the group formed by the three shots previously
fired. Fire three more shots and note the points
of impact on the target. Make additional
adjustment of the laser as necessary.