Replacement parts, Installation, Trouble - shooting – Kraus C-KCV-141-15000 User Manual

Page 2

Advertising
background image

Faucet body

Threaded pipe

O-ring

Rubber washer

Brass washer

Fixing ring

Mounting screws

Waterlines

1.

2.

3.

4.

5.

6.

7.

8.

Replacement Parts

Keep this manual for ordering replacement parts.

Trouble - Shooting

Problem

Cause

Action

Leaks underneath handle

Aerator leaks or has an inconsistent
water flow pattern.

Water will not shut off completely.

Adjusting ring or cap has come loose.

Aerator is dirty or misfitted.

Dirty or worn out plastic washer in the
cartridge.

Tighten the adjusting ring or cap.

Unscrew the aerator to check rubber packing
or replace the aerator.

Remove handle and cartridge to check if ceramic
disk is damage permanently or dirty.
Re-install cartridge.

Contact Us Toll-Free at 1-800-775-0703; or visit our website at www.kraususa.com 2008-2011 Kraus USA Inc.

Installation

Contact Us Toll-Free at 1-800-775-0703; or visit our website at www.kraususa.com 2008-2011 Kraus USA Inc.

1

2

Place the O-ring 2 over threaded pipe to the bottom
of the faucet body1. Then insert the threaded pipe 2
of the faucet body 1 into the drilled 1 3/8’’ hole of the
countertop.

1

3

4

5

6

7

8

Insert the rubber washer 4 and brass washer
5 on to the threaded pipe 3, then screw the
fixing ring 6. After place faucet body 1
correctly and tighten the mounting screws 7.
Screw waterlines 8 into the corresponding
screw-hole of faucet body 1.

2

1 3/8’’