Important safety instructions installing the hood, Electrical requirements, Intended use – FRIGIDAIRE FHWC3660LS User Manual

Page 5: Parts supplied, Important

Advertising
background image

5

GB

Electrical requirements

It is the customer’s responsibility:
• to contact a qualified electrical installer.
• to assure that the electrical installation is

adequate and in conformance with National
Electrical Code, ANSI/NFPA 70 – latest edition*,
or CSA Standards C22.1-94, Canadian Electrical
Code, Part 1 and C22.2 No.0-M91-latest edition**
and all local codes and ordinances.

If codes permit and a separate ground wire is
used, it is recommended that a qualified electrician
determines that the ground path is adequate.
• Do not ground to a gas pipe.
• Check with a qualified electrician if you are not

sure range hood is properly grounded.

• Do not have a fuse in the neutral or ground

circuit.

IMPORTANT

Save installation instructions for electrical
inspector’s use.
The range hood must be connected with copper
wire only.
The range hood should be connected directly
to the fused disconnect (or circuit breaker) box
through metal electrical conduit.

Wire sizes must conform to the requirements of
the National Electrical Code ANSI/NFPA 70 – latest
edition”, or CSA Standards C22.1-94, Canadian
Electrical Code Part 1 and C22.2 No.0-M91 – latest
edition** and all local codes and ordinances.

A U.L.- or C.S.A.-listed conduit connector must be
provided at each end of the power supply conduit (at
the range hood and at the junction box).

Copies of the standards listed may be obtained
from:
* National Fire Protection Association Batterymarch

Park Quincy, Massachusetts 02269

** CSA International 8501 East Pleasant Valley Road

Cleveland, Ohio 44131-5575

Power requirement:
120V~, 60Hz, 15 or 20A branch circuit

Intended use

• Your range hood is intended for exhaust operation

only. This range hood is not recommended to be
used over indoor grills. Do not use it to exhaust
hazardous or explosive materials or vapors.

Parts supplied

No. Part

Qty.

1

Range hood

1

2

Glass cover

1

3

Upper and lower

chimney

1
+
1

4

Upper bracket

1

5

Lower bracket

1

6

Collar

1

7

Recirculation kit

(optional

accessories)

-FHWRKT60LS

1

8

Bulb

20W, 120V~, GU10

(pre-assembled)

2

9

Bolt, rubber

washer, washer

4

sets

10

Long screw

(4mm x 32mm)

8

11

Wall plug

8

12

Short screw

(4mm x 12mm)

4

13

Allen key

1

14

Wood screw

(4mm x 50mm)

Short screw

(3.5mmx8mm)

4

15

Short screw

(3.5mmx8mm)

2

16

10’ extension

chimney kit

(optional

accessories)

FHW10X60LS

1

17

Template

(stencilled)

Assembly template

(stencilled)

1

Important safety instructions

Installing the hood

00-Elux FHWC3060LSA-Range hood-Book-01.indd 5

12/8/10 12:43 PM

Advertising