Installing the hood, Important – FRIGIDAIRE FHWC3660LS User Manual

Page 7

Advertising
background image

7

GB

• Flexible metal round ducts should only be used

when no other duct fitting exists. Limit use to
short lengths and do not crush when making
corners.

Examples of possible ducting or air
recirculation

Sidewall cap

Recirculator

Roof pitch with

flashing and cap

Pipe

Collar

Pipe

Pipe

Collar

Collar

fig.

Installing range hood to the wall
(Exhaust operation)

IMPORTANT

This range hood is very heavy. Adequate structure
and support must be provided in all types of
installations.

Install framing for hood support

• If drywall is present, mark the screw hole

locations.

• Cut away enough drywall to expose 2 vertical

studs at the holes location indicated by the
template. Install two horizontal supports at least
1” x 6” between two wall studs at the bottom and
top mounting holes installation location (fig. ).

• The horizontal support must be flush with the

room side of the studs. Use cleats behind both
sides of the support to secure to wall studs.

• Reinstall drywall and refinish.

• If open fireplaces are operated in the same room,

ask your local chimney sweeper about the local
regulations prior to installation.

• If you are renting, then approval must be obtained

from the owner of the property.

• Attention! In order for the range hood to reach

optimal performance, install it over the middle of
the cooking area.

• The following accessories are required to mount

the range hood (not included):

Exhaust duct

Power drill with 3/16” and 1/8” bits

Screwdriver

Level

Cable detector

Measuring tape

Duct tape

Ducting installation guidelines

• For safety reasons, ducting should vent directly

outdoors (not into an attic, underneath the house,
into the garage or into any enclosed space).

• Keep duct runs as short and straight as possible.
• Duct fittings (elbows and transitions) reduce air

flow efficiency.

• Back to back elbow and “S” turns give very poor

delivery and are not recommended.

• A short straight length of duct at the inlet of the

remote blower gives the best delivery.

• Transition to duct from the integral blower or

remote duct transition as close to the downdraft
as is possible.

• Use a suitable 6” round duct.

fig.

IMPORTANT

Framing must be capable of supporting 100 lbs.

Step 1:
• Make sure that no cables or pipes will become

damaged (e.g. electric, gas, water; test the areas
in question with a cable detector).

• Using supplied template (17), mark and drill 8

holes in the wall. Drill the holes according to the
measured distances from the diagram (fig. ).

• Upper/Lower bracket (4, 5): Insert 4 wall plugs

(11) into the 4 drilled holes.

• Range hood (1): Installation is depending on wall

type:

Wall type

Required fasteners

Wood

No wall plugs (11)
required

Brick/Concrete

4 wall plugs (11)

Installing the hood

Installing the hood

00-Elux FHWC3060LSA-Range hood-Book-01.indd 7

12/8/10 12:43 PM

Advertising