FRIGIDAIRE FPEF4085KF User Manual

40" electric range installation instructions

Advertising
background image

1

40" ELECTRIC RANGE INSTALLATION INSTRUCTIONS

P/N 318201706 (1201) Rev. A

English - pages 1 - 10

Español - páginas 11 - 20

Printed in Canada

**NOTE: 24" (61 cm) minimum clearance between
the cooktop and the bottom of the cabinet when the
bottom of wood or metal cabinet is protected by not less
than 1/4" (0.64 cm) fl ame retardant millboard covered
with not less than No. 28 MSG sheet metal, 0.015"
(0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum, or
0.020" (0.5 mm) copper.

30" (76.2 cm) minimum clearance when the cabinet is
unprotected.

Do not pinch the power supply cord between the range
and the wall.

Do not seal the range to the side cabinets.

Grounded

Wall Outlet

40 1/8" Min.

(101.9cm)

30" Min.**

(76.2cm Min.)

13" Max.

(33cm Max.)

18" Min.

(45.7cm Min.)

24" Min.

(61cm Min.)

24½" max.

(62.2cm Max.)

2¾" Min.

(7cm Min.) for

open door.

On left side

only, if there is a

wall

A. HEIGHT

B. WIDTH

C. DEPTH TO FRONT OF

RANGE

D. DEPTH WITH

DOOR OPEN

E. MINIMUM

CUTOUT WIDTH

F. HEIGHT OF

COUNTERTOP

48 1/8"

(122.2cm)

40 1/8"

(101.9cm)

26 1/4" (66.7cm)

with Handle 28 1/2" (72.4cm)

44 5/8 (113.3cm)

40 1/4" (102.2cm)

36" (91.4cm) standard

35 7/8" (91.1cm) min.

B

A

C

D

36 3/8"

(92.4cm)

36"

(91.4cm)

feet

extended

INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.

IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.

READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

FOR YOUR SAFETY: Do not store or use gasoline or other

fl ammable vapors and liquids in the vicinity of this or any other appliance.

United States

Advertising