40" electric range installation instructions – FRIGIDAIRE FPEF4085KF User Manual

Page 5

Advertising
background image

5

40" ELECTRIC RANGE INSTALLATION INSTRUCTIONS

Direct Electrical Connection to the Circuit
Breaker, Fuse Box or Junction Box

If the appliance is connected directly to the circuit
breaker, fuse box or junction box, use fl exible, armored
or nonmetallic sheathed copper cable (with grounding
wire). Supply a U.L. listed strain-relief at each end of
the cable. At the appliance end, the cable goes through
the Direct Connection Hole (see Figure 5) on the Cord
Mounting Plate. Wire sizes (copper wire only) and
connections must conform to the rating of the appliance.

Where local codes permit connecting the appliance-
grounding conductor to the neutral (white) wire
(see Figure 5):
1. Be sure that no power is supplied on the cable from

residence.

2. Remove the grounding strap from the terminal block

and from the appliance frame.

3. In the circuit breaker, fuse box or junction box:

a) Connect the green (or bare copper) wire, the white
appliance cable wire, and the neutral (white) wire
together.

b) Connect the 2 black wires together.

c) Connect the 2 red wires together.

Figure 5

3-Wire (Grounded Neutral) Electrical System

(Example: Junction Box)

Cable from Residence

Junction

Box

White Wire

U.L.-listed Conduit
Connector (or CSA
listed)

Cable from

Appliance

Green
(or Bare Copper)
Wire

Red
Wires

Neutral

(white) Wire

Black
Wires

NOTE: Be sure to remove the
supplied grounding strap.

Where local codes DO NOT permit connecting the
appliance-grounding conductor to the neutral
(white) wire, or if connecting to 4-wire electrical
system (see Figure 6):
1. Be sure that no power is supplied on the cable from

residence.

2. Remove the grounding strap from the terminal block

and from the appliance frame.

3. In the circuit breaker, fuse box or junction box:

a) Connect the white appliance cable wire to the

neutral (white) wire.

b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
d) Connect the green (or bare copper) grounding

wire to the grounding wire of the circuit breaker,
fuse box or junction box.

NOTE: Be sure to remove the
supplied grounding strap.

U.L.-listed Conduit
Connector (or CSA
listed)

Figure 6 – 4-Wire Electrical System

(Example: Junction Box)

Cable from Residence

Black
Wires

Junction

Box

White Wire

Cable from

Appliance

Green (or Bare
Copper) Wire

Red
Wires

White Wire

Green (or Bare
Copper) Wire

Advertising