Installing the hood, Important, Examples of possible ducting or air recirculation – FRIGIDAIRE FHPC4260LS User Manual

Page 8

Advertising
background image

8

Examples of possible ducting or air
recirculation

Recirculator

Roof pitch with

flashing and cap

Pipe

Collar

Pipe

Collar

Installing range hood to the ceiling
(Exhaust operation)

IMPORTANT

This range hood is very heavy. Adequate structure
and support must be provided in all types of
installations.

Step 1:
• Make sure that no cables or pipes will become

damaged (e.g. electric, gas, water; test the areas
in question with a cable detector).

• Using the template, mark and drill 4 holes into

the ceiling. Measure as displayed in diagram
(fig. ). The holes must be drilled into a wood

structure capable to support 150lbs load.

NOTE

Have a suitable ladder ready so that you can easily
reach up to the ceiling.

Desired range hood distance above a
36” high cooktop

Ceiling height

8 feet

9 feet

10 feet *

1

A*

2

A*

2

A*

2

24”

6-25/32"

25”

5-25/32"

26”*

3

4-25/32"

27”*

3

3-25/32"

28”*

3

2-25/32"

29”*

3

1-25/32"

13-25/32"

13-25/32"

30”*

3

25/32"

12-25/32"

12-25/32"

31”*

3

11-25/32"

11-25/32"

32”*

3

10-25/32"

10-25/32"

33”

9-25/32"

9-25/32"

34”

8-25/32"

8-25/32"

35”

7-25/32"

7-25/32"

36”

6-25/32"

6-25/32"

*1 with 10’ extension chimney kit (17) - not supplied.

Please call Electrolux at

1.800.944.9044 to order

this kit.

*2 “

Dimension A

” in the chart represents the height

from the top of upper bracket to the top of lower
bracket (fig. ).

*3 Recommended mounting height.

Dimension A

Top of upper bracket

Top of lower bracket

Installing the hood

10.24"

7.48"

10.24"

7.48"

Advertising